Tc-electronic TonePrint Editor User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
Modulation parameters
TC Electronic TonePrint Editor
Manual for software version 1.0 11
Through-Zero-Flanger parameter
Parameter range: 0 to 1023
When you set the Modulation Type parameter to
TZFlanger, delay line 1 becomes the “dry” part of
the signal. In that case, use the Through-Zero-
Flanger parameter to set the level ratio between
delay line 1 and delay line 2.
Speed parameter
Parameter range: 61.5 mHz (Millihertz) to 20 Hz
Use the Speed parameter to set the speed of
the chosen modulation effect. As setting of 1 Hz
means that one modulation cycle takes one se-
cond.
Depth 1 parameter
Parameter range: 0 to 100 %
Use the Depth 1 parameter to specify the inten-
sity of the effect. The value represents the ampli-
tude of the waveform modulating the signal.
When you have set Modulation Type to TZFlang-
er, you should set the Depth 1 parameter to a
value lower than Depth 2.
Depth 2 parameter
Parameter range: 0 to 100 %
The Depth 2 parameter is only applicable when
you have set Modulation Type to TriChorus or
TZFlanger.
In TriChorus mode, the Depth 2 parameter speci-
fies the intensity of the second chorus module. In
TZFlanger mode, the Depth 2 parameter speci-
fies the intensity of the second flange module.
The value represents the amplitude of the second
waveform modulating the signal.
Depth 3 parameter
Parameter range: 0 to 100 %
The Depth 3 parameter is only applicable when
you have set Modulation Type to TriChorus.
In TriChorus mode, the Depth 3 parameter speci-
fies the intensity of the third chorus module.
The value represents the amplitude of the third
waveform modulating the signal.
HiCut parameter
Parameter range: 20 Hz to 20 kHz
Use the HiCut parameter to reduce the high-end
frequencies in the modulation effect. Try using
this parameter if you feel the effect is too domi-
nant in your sound and turning down the Mix or
Output Level parameters doesn’t attenuate the
effect as intended.
Mix parameter
Parameter range: 0 to 100 %
Use the Mix parameter to set the relationship be-
tween the level of the dry signal and the level of
the modulation effect. If you have set Kill dry in
the Router section to On, this parameter has no
effect.
Output Level parameter
Parameter range: -100 to 0 dB
Use the Output Level parameter to set the overall
output level for the modulation effect.
Delay Time 1 parameter
Parameter range: 0.1 to 50 ms
As described earlier, a chorus or flanger is basi-
cally a delay being modulated by an LFO. Use
the Delay Time 1 parameter to change the length
of that delay. A typical chorus uses delay times
around 10 ms, while a flanger uses delays around
5 ms.
Although this is not how a chorus is normally
used, you may enjoy the “slap-back” sound re-
sulting from longer Delay Time values in the 30
to 50 ms range.
Delay Time 2 parameter
Parameter range: 0.1 to 50 ms
The Delay Time 2 parameter is only applicable
when you have set Modulation Type to TriChorus
or TZFlanger.
In TriChorus mode, the Delay Time 2 parameter
specifies the length of the delay for the second
chorus module.
In TZFlanger mode, the Delay Time 2 parameter
specifies the length of the delay for the second
flange module.
Page view 12